MINING TOOL
Mine Ventilation Pressure Drop Calculator
Estimate airway resistance, friction pressure loss and shock losses using the Atkinson equation.
Mine Ventilation Pressure Drop Calculator
FREE ONLINE TOOLSTEP BY STEP
How to use mine ventilation pressure drop calculator
- Check the input units and assumptions.
- Review the result and example.
IN PRACTICE
Example
Q=30 m³/s, A=12 m², P=14 m, L=500 m, k=0.012, ΣK=2, ρ=1.2: 51.25 Pa.
GOOD TO KNOW
Which formula and assumptions are used?
R = k L P / A³; Δp = R Q² + ΣK ρ (Q/A)² / 2. Single uniform airway; k in kg/m³ at actual air density, not a Darcy factor. Excludes leakage, network balancing, natural ventilation and fan selection.