Formula and units
Cylinder swept volume = piston area × stroke. For a double-acting cylinder, calculate cap-end and rod-end volumes separately. Approximate free air by multiplying chamber volume by absolute cylinder pressure ÷ atmospheric pressure. Multiply by cycles per minute for average flow.
Worked example
A 50 mm bore and 200 mm stroke has a cap-end volume of about 0.393 L. At 6 bar gauge, absolute pressure is roughly 7 bar, so extension uses about 2.75 normal litres of free air before allowances.
Assumptions and limits
Pressure must be converted to absolute pressure for the ratio. Real demand also depends on rod volume, dead volume, leakage, valve timing and the reference condition used for free air. Do not size a compressor from one actuator alone; total simultaneous demand and pressure drops matter.