Estima altura dinámica total y potencia a partir de caudal, presión y pérdidas.
Calculadora de bomba de pozo
HERRAMIENTA GRATUITA
Use the water level measured while pumping at the required flow, not the drilled depth or pump installation depth. Enter losses at that same flow, including the riser pipe and fittings.
Estimated duty point and power
Total dynamic head (TDH)
70.59 m
Pump shaft power
0.96 kW / 1.29 hp
Electrical input power
1.13 kW
Hydraulic power
0.58 kW
Head breakdown : 35 m + 30.59 m + 5 m = 70.59 m
For clean water (density 1,000 kg/m³). TDH = pumping lift + pressure head + entered losses. The pressure field is at the delivery point; for a free jet, include outlet velocity head in the losses. Efficiencies are assumptions until checked against manufacturer data.
Compare the flow and TDH with a manufacturer pump curve. Shaft power is an estimate, not a motor rating recommendation. Confirm well yield, submergence, bore diameter and electrical supply. This does not size a surface suction pump, pressure tank or cable.