Formula and units
Torque T (N·m) = 9,550 × shaft power P (kW) ÷ speed n (rpm). If power is electrical input rather than shaft output, motor efficiency must be considered before estimating mechanical torque.
Worked example
A motor delivering 5.5 kW at 1,450 rpm produces approximately 9,550 × 5.5 ÷ 1,450 = 36.2 N·m at that operating point.
Assumptions and limits
This is steady-state shaft torque. Starting torque, overload capability, service factor, gearbox losses and variable-load duty require manufacturer data. Use consistent units and the actual motor speed under load, not only synchronous speed.