Formula and units
Ideal force = pressure × effective piston area. Extension uses bore area A = πD²/4. Retraction uses annular area A = π(D² − d²)/4, where d is rod diameter. With MPa and mm², force in newtons = pressure × area; divide by 1,000 for kN.
Worked example
At 16 MPa with a 50 mm bore, extension area is 1,963.5 mm² and ideal force is about 31.4 kN. With a 25 mm rod, retraction area is 1,472.6 mm², giving about 23.6 kN.
Assumptions and limits
Actual force is lower due to friction and pressure losses. Confirm whether pressure is gauge pressure at the cylinder port, and use the actual bore and rod sizes. This estimate does not select a cylinder, valve, hose or safety factor.